GYPSUM BOARD SHAFT WALL SYSTEMS - SECTION 09275

A. Vertical Shaft Wall Assembly; System B: 1. UL Design U438, 2 hr, STC 39. Framing - steel studs 24 in. oc. Shaftside - vertical liner panels positioned into studs ...

Filetype:
Submitter: forsite
SUPPLEMENTARY INSTALLATION INSTRUCTIONS UL CLASSIFIED CURTAIN TYPE ...

1 1/2 HOUR LABEL, VERTICAL MOUNT ... for metal stud framing in UL resistant cavity shaft wall designs (1 and 2 hr.) including Nos. U438 ... assembly. 2. Damper Sleeve: Sleeve gauge ...

Filetype:
Submitter: properphar
FD, DFD,ODFD, and OFD Series FSD, OFSD and GFSD Series DFDR, FDR ...

Retaining angles for 11/2 hour ... apply to the following wall design numbers as detailed in the UL Fire Resistance Directory: U438, U469 ... Detail for I-Stud Assembly Detail ...

Filetype:
Submitter: babyypinkzz
Gypsum Board Partitions - Steel Framing STC - 38 OSU T-3296 WP ...

Chase wall, 5/8 (15.9 mm) Fire-Shield Gypsum Board applied vertically ... 2 Hour FIRE Design # UL U411 GA File # WP 1548 STC - 56 Sound Test # NGC-3022

Filetype:
Submitter: digaro
EWB-W142 Shaft Wall

... Liner Panels or U438 wt. 8 ... to studs, the assembly provides 2-hour fire ... 37 CGC Shaft Wall Systems System BULC Design W452, or W506, or UL Design U415, 2 hour fire ...

Filetype:
Submitter: fiddler13
UL Approved Fire Assemblies with Cellulose Insulation

... Assembly Assembly Beam U032 GF 1 Hour - Bearing U436 NW, GF 1, 2 ... U438 NW, GF 2 Hour ... Hour - Nonbearing V455 NW, GF 1 and 2 Hour Nonbearing U434 NW, GF 1 Hour - Bearing Wall ...

Filetype:
Submitter: pop125
System Design Considerations

U415 or U438). For a single-layer both sides, two-hour wall,apply 1/2 SHEETROCK ... 2 A A Section AA Wall assemblyUL System No. W-L-1027 (metal pipe); F ...

Filetype:
Submitter: big-d
Drywall/Steel Framed Systems

U419 or -hour UL Des. U438 2-hour 1 layer F IRECODE C Core 2 layers F IRECODE C Core 2 ... Deflection based on composite wall assembly without exterior finish. CGC Inc. SA923 ...

Filetype:
Submitter: buhspeene
BXUV.U465 - Fire Resistance

... Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly ... top and bottom edges of the wall. ... Copyright 2009 Underwriters Laboratories Inc.

Filetype:
Submitter: frazier31
SECTION 092900 - GYPSUM BOARD

CAVITY SHAFT WALL. Coordinate assembly with Section 09 22 16 ... Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: lornajoyce
Assemblies

U437, U438, U442, X526, X528 1/2 or 5/8 durock ... Fire rating for restrained assembly; 2 hour ... Joint Move- Comp- Assembly UL System Reference or Wall Type ...

Filetype:
Submitter: bigdiesel37
SECTION 09 22 16, NON-STRUCTURAL METAL FRAMING

Typical shaft wall assembly . 4. Typical fire rated assembly and ... 3.5 INSTALLING SHAFT WALL SYSTEM . A. Conform to UL Design No. U438 for two hour fire rating.

Filetype:
Submitter: nancyp
Gypsum Board Partitions - Shaftwalls

2008 ~ National Gypsum Company Cavity Shaftwalls 2 Hour FIRE Design # UL U498 GA File # WP 7079 STC - 40 Sound Test # NGC - 2618

Filetype:
Submitter: replicae42509
SECTION 09 29 00, GYPSUM BOARD

Typical shaft wall assembly. 4. Typical fire rated ... B. Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: petronillabonblolaabift
Design # Fire Rating Finish Rating Type Design # Fire Rating Type ...

UL Approved Fire Assemblies with NuWool Cellulose Insulation Wall Assemblies Floor Ceiling Assemblies Design ... U053 1 Hour - Nonbearing U438 2 Hour Nonbearing G543 ...

Filetype:
Submitter: mmschwartz
SECTION 09 29 00, GYPSUM BOARD

Typical shaft wall assembly. 4. Typical fire rated ... B. Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: dwnpxzig
Insulation Product Data Sheet

Acoustic performance of a wall assembly can be ... wall systems, SABs can achieve up to a 2 hour rating when tested ... UL U465 1 Hr. 47 W05182 Single Layer 5

Filetype:
Submitter: taylorbb6152

High Speed Downloads

ul u438 2 hour wall assembly - [Full Version]
13,544 downloads / 5,947 KB/s
ul u438 2 hour wall assembly - Full Download
4,949 downloads / 3,132 KB/s
ul u438 2 hour wall assembly - [Complete Version]
5,627 downloads / 3,847 KB/s
mugen 2d fighting games
WordPress Themes ThemeForest